Hebei Anmei Electrical Equipment Co., Ltd. is one of the most reliable manufacturers and suppliers of hv epoxy resin insulating bushing in China, also supports customized service. If you're going to buy high quality hv epoxy resin insulating bushing made in China, welcome to get quotation from our factory.

Special Characteristics
Compared with a porcelain OIP bushing, a dry-type epoxy resin bushing changes the failure mode, the maintenance schedule and the installation weight at the same time. An OIP bushing that fails under internal pressure can shatter a porcelain housing and release insulating oil; a cast epoxy bushing contains no oil to feed a fire and no brittle ceramic shell to produce projectiles, so the epoxy bushing fails without an explosion hazard. Maintenance requirements for epoxy bushings are lower than those for porcelain because there is no oil level to check, no gasket to re-tighten and no oil sampling interval to observe. On installation, an epoxy resin bushing removes the porcelain handling risk that drives breakage on retrofit projects, and its solid dry-type bushing construction eliminates oil leakage as a scheduled maintenance item. The trade-off is voltage range: epoxy bushings are commonly applied through medium-voltage and sub-transmission classes, while RIP and RIS constructions take over at the highest transmission levels. For medium-voltage transformer and switchgear applications, however, the high-voltage epoxy resin bushing delivers explosion containment, oil-free operation and a lower maintenance burden in a single dry-type bushing component - three system-level changes that a porcelain OIP bushing cannot match on its own.
Core Advantages
The core advantage of a high-voltage epoxy resin bushing is not a single specification, but a shifted failure mode and cost structure: it removes oil and brittle porcelain from the insulation path, replacing them with a one-piece cast epoxy body that fails safely, requires no routine oil or porcelain maintenance, and occupies less space at a lower installed weight. Practically, this means an epoxy resin bushing eliminates the explosion and oil-leakage risk inherent to porcelain OIP designs, cuts maintenance requirements for epoxy bushings to a fraction of porcelain by removing oil-level checks and gasket re-tightening, and delivers a lightweight, compact cast epoxy bushing that simplifies handling and supports denser transformer and switchgear layouts - with epoxy weighing less than 70% of an equivalent porcelain body and offering up to 15 times the flexural strength . For a buyer comparing a dry-type epoxy bushing against porcelain or GPO alternatives, the advantage is not marginal: it is a lower total cost of ownership driven by fewer failure paths, fewer maintenance interventions, and a smaller installed footprint.


Drawing
The drawing serves as the core basis for selection and installation of high voltage epoxy resin bushings, specifying key parameters such as flange dimensions, mounting openings, terminal configurations, creepage distance and overall outline to ensure precise matching of the epoxy resin bushing with the transformer tank cover and busbar interface. We provide standard technical drawings for each high voltage epoxy resin bushing, with our engineers verifying interfaces and electrical parameters against the drawings; customization of flange and terminal structures per customer drawings is also supported, making selection and installation straightforward.
Specification Table
| Sequence Number | Code | Model | Dimensions | Opening | Arcing distance | Creepage distance | Shield | Rod mode | Mounting flange | Weight(kg) | ||||
| H | h2 | h3 | d1 | Md | ||||||||||
| 1 | TH.FHA.011 | BFGW-40.5/315 | 580 | 122 | 40 | 180 | M12×1.75 | 105 | 365 | 1256 | 8L 9S | W | A | 9.5 |
| 2 | TH.FHA.012 | BFGW-40.5/315 | 504 | 84 | 2 | 180 | M12×1.75 | 105 | 365 | 1256 | 8L 9S | N | A | 9.5 |
| 3 | TH.FHD.024 | BFGW-40.5/630 | 600 | 132 | 50 | 180 | M20×2.5 | 105 | 365 | 1256 | 8L 9S | W | A | 10 |
| 4 | TH.FHA.013 | BFGW-40.5/315 | 660 | 122 | 40 | 180 | M12×1.75 | 105 | 445 | 1530 | 10L 11S | W | A | 10.9 |
| 5 | TH.FHA.014 | BFGW-40.5/315 | 584 | 84 | 2 | 180 | M12×1.75 | 105 | 445 | 1530 | 10L 11S | N | A | 10.9 |
| 6 | TH.FHD.025 | BFGW-40.5/630 | 680 | 132 | 50 | 180 | M20×2.5 | 105 | 445 | 1530 | 10L 11S | W | A | 11.6 |
| 7 | TH.FHA.020 | BFGPW-40.5/315 | 750 | 130 | 40 | 180 | M12×1.75 | 105 | 527 | 1650 | 12L 12S | W | A | 12 |
| 8 | TH.FHA.022 | BFGPW-40.5/315 | 674 | 92 | 2 | 180 | M12×1.75 | 105 | 527 | 1650 | 12L 12S | N | A | 12 |
| 9 | TH.FHD.014 | BFGPW-40.5/630 | 770 | 140 | 50 | 180 | M20×2.5 | 105 | 527 | 1650 | 12L 12S | W | A | 12.8 |
| 10 | TH.FHA.039 | BFGPW-40.5/315 | 670 | 130 | 40 | 180 | M12×1.75 | 105 | 447 | 1670 | 10L 10S | W | A | 11 |
| 11 | TH.FHA.049 | BFGPW-40.5/315 | 594 | 92 | 2 | 180 | M12×1.75 | 105 | 447 | 1670 | 10L 10S | N | A | 11 |
| 12 | TH.FHD.018 | BFGPW-40.5/630 | 690 | 140 | 50 | 180 | M20×2.5 | 105 | 447 | 1670 | 10L 10S | W | A | 11.6 |
| 13 | TH.FHA.038 | BFGPW-40.5/315 | 630 | 130 | 40 | 180 | M12×1.75 | 105 | 407 | 1450 | 9L 9S | W | A | 10.5 |
| 14 | TH.FHA.048 | BFGPW-40.5/315 | 554 | 92 | 2 | 180 | M12×1.75 | 105 | 407 | 1450 | 9L 9S | N | A | 10.5 |
| 15 | TH.FHD.017 | BFGPW-40.5/630 | 650 | 140 | 50 | 180 | M20×2.5 | 105 | 407 | 1450 | 9L 9S | W | A | 11 |
| 16 | TH.FHA.024 | BFGPW-40.5/315 | 590 | 130 | 40 | 180 | M12×1.75 | 105 | 367 | 1260 | 8L 8S | W | A | 9.7 |
| 17 | TH.FHA.025 | BFGPW-40.5/315 | 514 | 92 | 2 | 180 | M12×1.75 | 105 | 367 | 1260 | 8L 8S | N | A | 9.7 |
| 18 | TH.FHD.016 | BFGPW-40.5/630 | 610 | 140 | 50 | 180 | M20×2.5 | 105 | 367 | 1260 | 8L 8S | W | A | 10.2 |
| 19 | TH.FHA.053 | BFGPW-40.5/315 | 590 | 130 | 40 | 160 | M12×1.75 | 105 | 366 | 1256 | 8L 8S | W | B | 9.7 |
| 20 | TH.FHA.058 | BFGPW-40.5/315 | 514 | 92 | 2 | 160 | M12×1.75 | 105 | 366 | 1256 | 8L 8S | N | B | 9.7 |
| 21 | TH.FHD.028 | BFGPW-40.5/630 | 610 | 140 | 50 | 160 | M20×2.5 | 105 | 366 | 1256 | 8L 8S | W | B | 10.2 |
| 22 | TH.FHA.054 | BFGPW-40.5/315 | 670 | 130 | 40 | 160 | M12×1.75 | 105 | 446 | 1520 | 10L 10S | W | B | 10.5 |
| 23 | TH.FHA.059 | BFGPW-40.5/315 | 594 | 92 | 2 | 160 | M12×1.75 | 105 | 446 | 1520 | 10L 10S | N | B | 10.5 |
| 24 | TH.FHD.029 | BFGPW-40.5/630 | 690 | 140 | 50 | 160 | M20×2.5 | 105 | 446 | 1520 | 10L 10S | W | B | 11 |
Material Requirements
Resin and Curing System
A high-voltage resin bushing is defined first by its resin and curing system. Outdoor-grade epoxy resin bushings use a cycloaliphatic epoxy resin with an anhydride hardener for tracking and erosion resistance and a glass transition temperature high enough for thermal cycling. A production cast epoxy bushing must also control viscosity and pot life, since incomplete wetting becomes a partial discharge site.
Fillers and Fiber Reinforcement
The second requirement covers the silica filler system and glass-fiber reinforcement. Silica filler matches thermal expansion to the conductor and raises thermal conductivity; production epoxy resin bushings use silanized silica flour to avoid moisture-driven partial discharge. Where strength is specified, epoxy-impregnated glass fiber must form a void-free fiber-resin composite.
Metal Inserts and Sealing Interface
The third requirement governs metal inserts and the sealing interface. A cast epoxy bushing embeds a metal insert positioned so bolt torque does not crack resin and oil leakage does not develop; aluminum flange inserts reduce voids through matched thermal expansion. The sealing interface must use a fully confined gasket, or it becomes the first leak path on an epoxy resin bushing.
Scope of Application
High-voltage resin bushings are applied wherever a solid, oil-free insulation body replaces porcelain or oil-impregnated paper. In power transformers, distribution transformers and dry-type transformers, the epoxy resin bushing is the winding-to-network interface and eliminates oil-level maintenance and porcelain fragmentation risk. In high-voltage switchgear, ring main units and box-type substations, the epoxy bushing provides compact phase-to-ground insulation, which is why solid-insulated switchgear depends on cast epoxy resin bushings. In GIS and cable terminations, epoxy composite bushings act as barrier penetrations and must hold partial discharge performance under gas atmospheres. Beyond grid equipment, epoxy resin bushings serve wind power, photovoltaic, energy storage, industrial power equipment and rail transit, where vibration, humidity and space constraints favor a cast epoxy bushing over porcelain.
Company Description

About Hebei Anmei
Hebei Anmei Electric Equipment Co., Ltd. is a professional transformer bushing manufacturer with over 30 years of industry experience, located in Hejian City, Hebei Province, China. The company owns its own factory and focuses on the R&D, production, and sales of transformer bushings. Its products cover high-voltage (up to 40.5kV) and low-voltage series, with insulation types including porcelain, cast resin, and silicone rubber, and can be manufactured according to international standards such as DIN, ANSI, EN, AS, and ABNT. These products are mainly used in oil-immersed distribution and power transformers. With strict quality control, all finished products undergo routine electrical tests. The company supports customized drawings, sample processing, and OEM/ODM cooperation, serving transformer manufacturers and power engineering customers in many countries and regions.
Our Advangtage
Your Strategic Partner in Transformer Insulation
Agile Supply Chain & Guaranteed Lead Times
With a fully integrated in-house supply chain-from mold development to final assembly-we eliminate the risks of outsourced delays. This closed-loop manufacturing system allows us to maintain highly stable lead times, even for large-volume and urgent custom orders, ensuring your project timelines are never compromised.
Advanced Engineering & Customization
We don't just manufacture to drawings; we offer engineering problem-solving. Backed by 30 years of industry know-how, our technical team can optimize your bushing designs for better creepage distances, material compatibility, and installation efficiency, ensuring the final product perfectly adapts to your specific transformer designs.
One-Stop Transformer Accessory Solution
Beyond high-quality bushings, we provide a comprehensive accessory ecosystem. From oil level gauges and dehydrating breathers to protective covers, we supply a complete range of transformer components. This one-stop sourcing capability significantly reduces your procurement costs, supplier management time, and logistics complexity.
Flexible Prototyping & 24H Rapid Response
We understand the importance of speed in project bidding. We support flexible small-batch prototyping and sample processing to validate designs quickly. Furthermore, our dedicated sales and engineering team guarantees a professional response to all technical inquiries and RFQs within 24 hours.

Remarkable Service
Pre-sales consultation
Our technical engineers provide professional consultation on bushing selection, drawing customization, and installation to ensure a perfect match for your transformers.
Cost saving
Factory-direct pricing and one-stop sourcing for bushings and related accessories significantly reduce your procurement costs and supplier management time.
Stable delivery
100% routine electrical tests (including partial discharge and voltage withstand) are conducted before shipment. Official test reports are provided.
Authoritative inspection
Professional quality inspectors will conduct a quality inspection on each batch of products. Authoritative test reports are also available.
Win-win cooperation
We support flexible OEM/ODM services and build long-term strategic partnerships to achieve mutual growth and success with global clients.
Workshop

Our Certificate

GB/T 45001-2020 / ISO45001:2018
GB/T19001-2016 / ISO9001:2015
GB/T24001-2016 / ISO14001:2015
The Interfaces Between: Where a High-Voltage Resin Bushing Actually Fails
1. Failure location. A high-voltage resin bushing fails at the interfaces between materials, not inside any single material.
2. Core–resin interface. Differing thermal expansion coefficients concentrate stress at the interface between the fiber-reinforced core and the cast epoxy body, producing interface delamination that becomes a partial discharge site.
3. Insert–resin interface. The metal insert/epoxy interface is the weakest part of the internal insulation; thermal expansion mismatch creates stress concentration, and curing-stage microcracks propagate until surface discharge initiates.
4. Flange–resin interface. At the sealing interface between the metal flange and the epoxy body, differential thermal expansion drives oil leakage unless a flexible membrane or fully confined gasket is used.
5. Process control. Vacuum casting removes voids at the core-resin and insert-resin interfaces, APG suppresses internal air gaps, and controlled curing limits thermal stress.
6. Verification. A cast epoxy bushing meeting a partial discharge limit of 3–5 pC proves all three interfaces are void-free - one defective interface fails the test.
FAQ

01.When should I choose a high-voltage resin bushing instead of a porcelain or OIP bushing?
02.Can you customize bushings for special environments like high altitude or heavy pollution?
03.What routine tests does a high-voltage resin bushing go through before shipment?
04.What do arcing distance and creepage distance mean?
05.Do you customize bushings per our drawings?
06.What is your lead time?
Hot Tags: hv epoxy resin insulating bushing, China hv epoxy resin insulating bushing manufacturers, suppliers, factory, transformer cable bushing, transformer current transfer bushing, transformer industrial insulation bushing, transformer insulated feedthrough